TM 10-5411-200-14T.O. 35E4-177-14-6. (cont)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION—8.NO POWER AT ONE OR BOTH EXTERIOR UTILITY OUTLETS.Step 1.Check and reset circuit breaker CB8.Replace defective circuit breaker (paragraph 4-7).Step 2.Test operation of associated exterior utility outlet andwiring (paragraph 4-13).a.Replace defectiveb.Replace defectiveSection III. ORGANIZATIONALwiring (paragraph 4-13).outlet (paragraph 4-13).MAINTENANCE PROCEDURESThis section contains the following maintenance procedures for the shelter.LIST OF FUNCTIONSFunctionFunction Ref.No.12345678910Function(paragraph)Circuit Breaker Panel Assembly Testing, Replacement andRepair (Models NQOB and NQOD)Replacement of Obsolete NQOB Circuit Breaker Panel WithNew NQOD Circuit Breaker PanelPower Entry Panel Assembly Testing, Replacement and RepairArea Light Assembly Testing and RepairIncandescent Light Assembly Testing, Replacement and RepairHinged Roof Area Ceiling Light Testing and RepairFixed Roof Area Ceiling Light Testing, Replacement and RepairReceptacle Outlets Testing, Replacement, and RepairWall Switches ReplacementBlackout Switch Replacement, Repair, and AdjustmentWiring Testing, Replacement, and RepairPersonnel and Right Cargo Door Replacement, Repair, andAlignmentLeft Cargo Door Replacement, Repair, and AlignmentHinged Panel Leveling Jack Assemblies Service and RepairHinged Roof Panels Service, Replacement, Repair, and AlignmentHinged Endwall Replacement and RepairHinged Sidewalls Replacement and RepairHinged Floor Panel Replacement and Repair4-74-7.14-94-84-104-114-124-134-144-154-1611121314151617184-174-184-194-204-214-224-23CHANGE 24-5