TROUBLESHOOTING PROCEDURES
0008 00-2
2.
THIS PROCEDURE COVERS:
Lights inoperative
INITIAL SETUP:
Maintenance Level
Materials/Parts
Operator
Bulb, 50 watt, double tube, 4 pin
Table 0008 00--1. Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Lights inoperative
WARNING
Lethal voltage is present when
light set is connected to power
source. Disconnect power
before inspecting or repairing
any part of the light set.
1. If all lights are inoperative,
1. Ensure an external power
check external power and cable
source (commercial or a
connection to distribution box
generator providing 110V AC) is
as in procedure 1.
connected to distribution box.
Refer to Work Package 0005-00
2. Check light circuit breaker at
2. Reset light circuit breaker.
distribution box.
3. If only individual light(s) are
3. Reconnect power cable(s)
inoperative, check the power
correctly.
cable(s) for proper connection.
4. Check fluorescent bulbs on
4. Replace fluorescent bulbs on
individual, inoperative lights.
individual, inoperative lights.
Refer to Work Package 0020
00.
5. If condition persists or light
circuit breaker activates
repeatedly, notify unit
maintenance.