TM 10-5410-224-14
1-7. Tabulated Data.
b. A lifting ring and stud are mounted on each
top comer of the center structure. Double cargo
Located on personnel panel
Identification Plate . . . . . . . . . . . . .
doors (one with a vent) are installed in one end
door
panel of the center structure, and a personnel door
Contains:
Equipment nomenclature
also with a vent is in the. other end panel. Four
Type and designation
step assemblies are mounted on the outside of one
number
of the cargo doors to provide access to the shelter
Manufacturer's
part
roof. A lift sling drop pad and roof handle are
number, name, and code
mounted on the center structure roof.
Contract number
Serial number
c. The two foldout end walls of the expandable
National stock number
shelter are designed to accommodate ventilation
Erection Sequence Instruction Located on personnel panel
fans and environmental control units (ECU). The
door. Contains sequence and
Plate . . . . . . . . . . . . . .. . . . . ..
ventilation fans are installed when ECU units are
instructions for erection of
not available. When ECU's are available and
the expandable shelter.
Exterior Dimensions (Stowed
installed in the foldout end walls, the ventilation
Dimension
Shelter)
fans are not used and are left in the storage
Width . . . . . . . . . . . . . . 8 ft (2.44 meters)
location. Separate power cables each with circuit
Height.................... 7 ft, 11 in. (2.41 meters)
L e n g t h . . . . . . . . . . . . . . . . 13 ft, 4 in. (4.06 meters)
breaker protection are provided in the shelter for
Exterior Dimensions (Deployed
the ventilation fans and for the ECU's. Separate
Dimension
Shelter)
control switches are also provided for the ven-
22 ft, 3 in. (6.78 meters)
Width . . . . . . . . .
tilation fans.
7 ft, 11 in. (2.41 meters)
Height.
L e n g t h . . . . . . . . . . . . . . . . 13 ft. 4 in. (4.06 meters)
Interior Dimensions Dimension
on the outside of the personnel end panel. A
Minimum clear height . 6 ft, 9 in. (2.06 meters)
connector on this panel receives the primary input
Minimum clear width width
power for the expandable shelter from an external
( s t o w e d m o d e ) 6 ft, 6 in. (1.98 meters)
source and routes it to a circuit breaker panel on
Total Weights . . . . . . . . . . . . . . . Weight
the inside of the personnel end panel. The power is
Less payload . . . . . . . . . . . . . . . . . 4200 lbs (1905 kilograms)
then distributed by the circuit breaker panel to
With payload (maximum) . . . . . . . . . . . 6000 (2721 kilograms)
Primary Power Requirements . . 120/208 Vac,
internal lights and outlets and to the ventilation
60 Hz, 3 phase, 5 wire
fans and/or ECU's. Power from the circuit breaker
Environmental Limits . .. . . . . . . Limit
panel is also made available at two utility outlets
Operating temperture . . . . . . . . . -25F to'+ 125F
located on the power entrance panel. Either one of
(-31.7% to 51.7C)
the utility outlets can be used to supply power to
Maximum outer skin tem-
the exterior light assembly which is normally
perature. . . . . . . . . . . . . . . . . +200 (93.3C
Transportability (Stowed
attached to the personnel end panel next to the
Shelter). . . . . . . . . . . . Method
personnel door. However, the exterior light
Air.. . . . . . . . . . . . . . .. . . . .By aircraft, using 463L, or
assembly may also be attached next to the cargo
MH5.1.1970 cargo handling
doors. For this purpose, the light is supplied with
system, or suspended from a
helicopter.
a 25-foot (7.5 meters) cable so that it can be routed
Water . . . . . . . . . . . . . . . . . . . . . . . . By any mutable water vessel.
from the utility outlet over the roof of the shelter
Rail. . . . . . . . . . . . . . . . . . . . . . . . . .On a standard railway car as
to the cargo side.
used in the continental
United States, in accordance
1-6. Differences in Models.
with methods and standards
in the loading rules of the
This manual only covers the expandable shelter.
Association of American
Railroads.
Land . . . . . . . . . . . . . . . . . . . . . . By truck, fiat bed trailer,
1-4