TM 10-5410-223-14/1
3. LOOSEN SCREWS SECURING CLAMPS OVER THE AIR LOCK ADAPTER FRAME.
LIFT THE AIR LOCK ADAPTER OUT AND DOWN FROM THE SHELTER CAP.
TS 016754
Figure 4-11. Air lock adapter, removal (sheet 3 of 3 ).
b. Repair. Repair of the air lock adapter consists
(1) Application of adhesive. Apply adhesive for
of minor patching using those instructions listed
installation of patches to cover holes or other
below. Report major damage to Direct Support
damage to fabric, to recement seams and to replace
Maintenance.
damaged cemented fabric as follows:
NOTE
Two fabric repair kits are furnished with each combat
Adhesives and solvents are highly flam-
support hospital and evacuation hospital. The fabric
mable; perform work in well-ventilated area
repair kit is to be used in making fabric repairs to
components of the shelter.
4-46