TM 9-4931-374-13&P
MODIFICATION
1
SIX 0.406-IN. (1.031-CM) DIAMETER
HOLES (1).
Drill in table (2) using
NOTE
supports (3) placed flush with back of table
Modification procedures are
as templates.
used
only
for
initial
installation or when the table
has been replaced with a new
unit.
Install table in frame before
starting
modification
procedures.
2
TWO 0.406-IN. (1.031-CM) DIAMETER HOLES (4). Drill in frame (5)
using long brace (6) and long brace (7) as templates.
3-169