TM 9-4931-374-13&P
5
WINGNUT (7). Remove.
6
LOCKWASHER (4), GROUND WIRE (8),
AND FLAT WASHER (6). Remove.
7
TWO NUTS (9) AND
TWO
FLAT
WASHERS (6). Remove.
8
STUD (10). Remove.
INSPECTION
SERVICE
REPAIR
Inspect all parts for rust, corrosion, or other
Replace any parts that are broken, cracked, or
defects.
otherwise damaged in any way that would
prevent good electrical contact (app C).
NOTE
The grounding stud, mounted
Clean any rusted or corroded parts by brushing
NOTE
through the power input
with a wire brush or abrasive cloth (item 4, app
For initial installation only
panel, is used to connect a
D).
remove
grounding
stud
grounding rod on the exterior
furnished with shelter and
of the shelter for grounding
then proceed with reassembly
the shop set electrical system
steps 1 thru 5.
and the shelter itself.
3-113