TM 9-2330-379-14&PEMERGENCY RELAY VALVES - CONTINUEDACTIONLOCATIONITEMREMARKSINSTALIATIONNOTEAnti-seize tape, type II (item 8, Appendix E) shall beapplied to all threads when assembling fittings excepton emergency relay valve.NOTEApply pipe sealant (item 9, Appendix E) to all threadswhen assembling fittings in emergency relay valves.11ServiceRear dolly a.Apply Antiseize tape to threads onbrakes airemergency relay1/2 x 3/4 adapter (3) that will matereservoirvalve (2) andwith service brakes air reservoir tanktank (1) 1/2 x 3/4 (1) and screw adapter into airadapter (3)reservoir tank.b. Attach rear emergency relay valve (2)to other end of adapter (3).12 Emergency relay a.Attach street tee (6) to emergencyvalve (2), tworelay valve (2).hose assemblies b.Apply Antiseize tape to threads on two(4) and (5), andhose assemblies (4) and (5) and attachstreet tee (6) two hose assemblies to street tee (6).13Emergency relaya.Attach 3/8 street elbow (8) tovalve (2), hoseemergency relay valve (2).assembly (7) andb.Apply Antiseize tape to threads of3/8 street elbowother end of street elbow (8) and(8)attach hose assembly (7).14Emergency90’ street elbowa.Attach 900 street elbow (9) torelay valve (9) and hoseemergency relay valve (4).(4) assembly (10)b.Apply Antiseize tape to threads ofother end of 900 street elbow (9) andattach hose assembly (10).4-134