TM 9-2330-379-14&P
UNIT TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. SLOW APPLICATION OR SLOW RELEASE OF BRAKES
Step 1. Check for proper operation of air supply system components.
Repair/replace defective air supply system components. If air supply system
operates properly
go to step 2.
Step 2. Check for weak or broken brake shoe return spring(s) (1) (page 4-103).
Replace brake shoe return spring(s) (page 4-103).
Step 3. Refer to page 4-79 for additional brake system maintenance information.
4-29