TM 10-8340-240-12&P
0004 00-1
MODULAR GENERAL PURPOSE TENT SYSTEM (MGPTS)
0004 00
OPERATION UNDER USUAL CONDITIONS
These instructions are based on the
medium MGPTS. For other tent sizes, the
number of Mid Sections and poles will differ.
Make modifications as required.
SITE SELECTION
Select an area to erect the tent. Ensure the area will be large enough for the tent and guy ropes
that will be erected (see Table 0004 00-1). The area should be clear of trees, rocks and debris.
Choose a relatively flat area, the ground should not vary by more than 6 inches. A trench should
be dug around the perimeter of the tent about 2 feet away from the edge. A drainage ditch should
also be dug for water to exit the perimeter trench.
LAYOUT FABRIC SECTIONS
a. Identify each Fabric Section required. For the medium MGPTS you will need two End
Fabric Sections and one Mid Fabric Section.
Fabric Sections are heavy. Observe lifting
requirements printed on the tent and pole
bags. Always lift with your legs not your
back. Failure to observe this warning may
result in back injury.
b. Transport each required fabric section into area where tent will be erected.
c. Unfold each End Section (2) and Mid Fabric Section (1) so that the inside (white side) is down
and the green side is up. Place these sections in center area where tent is to be setup. (See
Figure 0004 00-1).
Table 0004 00-1 Area Setup
Requirements
AREA SETUP REQUIREMENTS:
Tent
Length
Width
Height
Small
34 ft
34 ft
12 ft
Medium
52 ft
34 ft
12 ft
Large
70 ft
34 ft
12 ft