TM 10-7310-281-13&PMODERN BURNER UNIT (MBU)0005 00OPERATION UNDER USUAL CONDITIONS0005 00-22Table 1. MBU Fault IndicatorsIndicator - colorIndicator Normally LitIf LitBeforeOperationIf Lit While MBU IsOperatingIf Lit AfterAutomaticShutdownWARMUP - amberFirst two minutes ofMBU operation.N/ANormal first twominutes ofoperation, abnormalafter two minutes.N/ARUN - greenAfter two minutes ofoperation. WARMUPindicator tuns off at thesame time.N/AAbnormal first twominutes ofoperation, normalafter two minutes.N/AFUELING/FULL(green)blinking/steadyWhen fuel tank isfilling/full.N/AN/AN/ALOW FUEL –indicators light asfollows:After approximately 3hours of operation, andfor ½ hour thereafter, forthe times indicated:- green (blinking)For 15 minutes- amber (blinking)For 7-1/2 minutes- red (blinking)For 7-1/2 minutes- red (steady)On MBU shut-down,hour from when LOWFUEL initially blinkedgreen.Fuel tank needs to be filled.NOTE!If the MBU is manually shut down while the LowFuel indicator is lit, it will not restart until it isrefueled.VOLTAGE (red)At an automaticshutdown when supplyvoltage falls to less than22 V DC or greater than29.5 V DC.Checkpowersource forproperoperation.N/ACheck powersource forproperoperation..SERVICE (red)Troubleshoot the problem (WP 0009). Attempt are-start of MBU.HOUR METERBACK LIGHT -greenWhen power is on.N/AN/AN/A