TM 10-5410-221-14/1
1. Bolt (5)
18.
Cover ay
35.
Bolt (8)
52. Skid ay (2)
2. Washer (5)
19.
Cover ay
36.
Washer (8)
53. Bolt (22)
3. Cover ay
20.
Cover ay
37.
Washer (8)
54. Channel (2)
4. Rivet (5)
21.
Cover ay
38.
Support ay
55. Rivet (14)
5. Hinge
22.
Cover ay
39.
Spacer
56. Nut plate (22)
6. Gasket
23.
Screw
40.
Blind nut
7. Gasket
24.
Cover ay
41.
Detent pin
58. Panel ay, fixed floor
8. Gasket
25.
Rivnut (16)
42.
Screw
*58. Floor covering
9. Pin
26.
Screw (6)
43.
Screw
**59. Seal (2)
10. Fastener, stud
27.
Washer (6)
44.
Washer
**60. Seal (2)
11. Bolt (13)
28.
Towing bracket (4)
45.
Ground rod
61. Screw (64)
12. Washer (13)
29.
Blind nut (6)
46.
Rivet (4)
62. Screw (54)
13. Bulkhead ay
30.
Screw (6)
47.
Seal angle (2)
63. Hinge half (2)
14. Bulkhead ay
31.
Washer (6)
48.
Guard
64. Panel ay, fix floor
15. Seal
32.
Washer (6)
49.
Guard
16. Screw (58)
33.
Mobilizer bracket
50.
Bolt (38)
17. Screw (12)
34.
Channel insert
*Installed on shelter No 1 thru 184 only.
**Installed on shelter serial No. 185 thru 302 only
(1) Cement seals.
(7) Remove ring assembly (28 and 29) from panel by
removing bolt (25), washers (26 and 27). Separate fitting
two part adhesive from the repair kit.
(33) from ring assembly (28 and 29) by removing screws
g. Installation. Install the water box fixed end panel
(30) and washers (31 and 32).
in reverse order of removal using FO-7 (located in back
(8) Remove plate (35) by removing rivets (34).
of manual) as a guide.
(9) Remove steps (38) by removing bolt (36) and
washer (37).
8-14. Fixed Floor Panel Assembly
(10) Remove striker plate (41) by removing screw
(39). Remove insert (40) by drilling out using a drill bit
a. General. The fixed floor panel assembly is a
the same diameter as the insert.
metal faced honeycomb core panel housing the shelter
(11) Remove bracket (-15) and spacer (.14) by
water tunnel and electrical raceway.
It provides
removing bolt ( 12) -and washer (43).
mounting for the shelter skid assembly. On shelter serial
(12) Remove latch assembly (47) by removing screw
No. 1 thru 184 only, the interior face is covered with a
(46).
(13) Remove screw (48), washer (49) and remove
b. Removal. Remove the fixed floor panel assembly
clamp assembly (50). Remove cable assembly (51) and
as required to replace damaged parts as follows.
remove lock wire and unscrew hook (52) from turnbuckle
(1) Remove fixed end panels, fixed roof panels and
(53). Unscrew turnbuckle (53) from terminal (54).
water box assembly according to procedures outlined in
(14)Remove screw (55) and remove capstan (56)
from panel.
(2) Remove hinge pins from hinge halves and
(15) Remove screw (57), washer (58) and remove
spacer (59). Remove insert (60) by drilling out using a
drill bit with same size diameter as insert.
NOTE
(16) Remove tie down assembly (62) by removing
Block up folding portion of shelter after
rivet (61).
removal from fixed portion to prevent
(17) Remove spacer (64) by removing screw (63).
any possible damage to panel
(18) Remove bolt (65), washers (66 and 67) and
assemblies.
remove guide assembly (68) from fixed end panel (69).
(d) Repair. Repair damage to honeycomb panel
c. Disassembly. Disassemble the fixed floor panel
assembly as required to replace damaged part according
If
to sequence of index numbers assigned to figure 8-9 and
possible, straighten any bent plates, latches, angles, or
observing the following:
extrusions using hammer, pliers, vise or other suitable
(1) Remove cover assembly (3, fig. 8-9) by removing
tool.
e. Overhaul. Overhaul the water box fixed end
bolt (4) and washers (2). Remove hinge (5) from cover
(3) by removing rivets (4). Remove gasket (6m, 7 and 8)
panel assembly as required to return to a serviceable
from cover assembly (3) by peeling from cemented area.
condition (chap. 8, sec. III).
f. Assembly. Assemble the folding roof panel in
Remove pin (9) and remove fastener stud (10) from
cover assembly (3).
reverse order of disassembly using FO-7 (located in the
back of manual) as a guide and observing the following:
Change 1, 8-23