TM 9-2330-390-14&P
4-61. AIRBRAKE CHAMBER REPLACEMENT (Cont).
FRONT DOLLY AIRBRAKE CHAMBER
REAR DOLLY AIRBRAKE CHAMBER
b.
CLEANING AND INSPECTION
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective
goggles and gloves, and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame or
excessive heat. The solvents flash point is 100°F-138°F (36°C-59°C). If you
become dizzy while using cleaning solvent, immediately get fresh air and medical help.
If solvent contacts eyes, immediately wash your eyes and seek medical attention.
1.
Clean silicone compound from housing assembly tube with a rag dipped in dry cleaning solvent.
2.
Inspect airbrake chamber and spanner nut for damage. Replace damaged spanner nut and airbrake chamber.
3.
Remove, clean, and inspect wedge assembly inside plunger housing as required (see paragraph 4-60).
4-137