TM 10-5411-224-14
TABLE 4-1. UNIT TROUBLESHOOTING - continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. SHELTER ROOF HANDHOLD DOES NOT FUNCTION PROPERLY.
Step 1. Inspect shelter roof handhold for adequate lubrication.
Lubricate as required (appendix G).
Step 2. Inspect handhold for damage or loose or missing hardware.
If handhold is damaged, notify your supervisor.
5. LADDER ASSEMBLY DOES NOT MOUNT PROPERLY.
Step 1. Inspect ladder for damage.
Replace ladder as required (paragraph 4-15).
Step 2. Inspect stowage brackets and strap for damage or loose hardware.
Tighten hardware and replace components as required (paragraph 4-16).
Step 3. Inspect deployed brackets for damage or loose hardware.
Tighten hardware or replace brackets as required (paragraph 4-12)
6. SHELTER PADS DAMAGED.
Step 1. Inspect pads for major damage.
Replace pads as required (paragraph 4-13).
7. SHELTER LIFTING RING BUMPERS DAMAGED.
Step 1. Inspect lifting ring bumpers for major damage.
Notify your supervisor if bumpers need to be replaced.
8. DOOR HOLDER DOES NOT PROPERLY ENGAGE.
Step 1. Inspect door holder for damage or loose or missing hardware.
Repair or replace as required (paragraph 4-14).
4-14