TM 10-5411-200-14
T.O. 35E4-177-1
4-23.
(cont)
10.
Drill out blind rivets (19) and remove shear plate (20).
(Refer to
paragraph 4-32
CLEANING, INSPECTION
1.
Clean panel and component surfaces.
2.
Inspect mounting surfaces for corrosion and damage.
3.
Inspect for and replace if necessary:
a.
Missing or damaged components
b.
Corrosion or paint damage.
Repair
1.
Panel skin damage.
(Refer to paragraphs 4-31 through 4-42.)
2.
Corrosion or paint damage.
(Refer to paragraph 4-43)
4-113