TM 10-5411-200-14
T.O. 35E4-177-1
4-12. (cont)
2.
3.
4.
5.
C A U T I O N
When removing end caps, hold safety tube level to
prevent fluorescent tube from accidentally sliding
out and dropping.
Remove split retaining rings (13) from one end of fluorescent lamps (14).
Remove two fluorescent lamps (14) with light shields (15) by rotating and
sliding out of light frame (3).
Remove light shields (15) from
fluorescent lamps (14).
NOTE
Tag all wires for reconnection.
Remove two wire nuts (9) and separate two sets of wires between ballast
(16) and contacts on light frame (3).
Remove four wire nuts (9) and separate four sets of wires between
ballast (16) and contacts at opposite end of light frame (3).
4-34