Table 3-1.  OPERATOR TROUBLESHOOTING - TM-10-5410-229-13P_84
TABLE 3-1.  OPERATOR TROUBLESHOOTING CONTINUED - TM-10-5410-229-13P_86

TM-10-5410-229-13P Modular Command Post System (MCPS) Green NSN 5410-01-323-2454 Tan NSN 5410-01-334-7529 Manual
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
TM 10-5410-229-13&P TABLE 3-1.  OPERATOR TROUBLESHOOTING CONTINUED MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 2. LUMINAIRES DO NOT LIGHT. Step 1. Check power source. Select proper power source (110V AC 50/60 HZ) Step 2. Check to make sure all electrical connectors are properly connected. Connect electrical connectors. Step 3. Check for bad fuse (glass enclosed wire will be broken/burnt). Replace fuse if necessary as described in paragraph 3-6. Step 4. Check for burnt-out fluorescent lamp (lamp will be gray/black). Replace lamp as described in paragraph 3-4