• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
LOCATION AND DESCRIPTION OF MAJOR PARTS - Contd
LOCATION AND DESCRIPTION OF MAJOR PARTS - Contd. - TM-10-5410-229-13P_19

TM-10-5410-229-13P Modular Command Post System (MCPS) Green NSN 5410-01-323-2454 Tan NSN 5410-01-334-7529 Manual
Page Navigation
  1    2    3    4    5  6  7    8    9    10    11  
TM 10-5410-229-13&P 1-10. LOCATION AND DESCRIPTION OF MAJOR PARTS - Cont’d. Two, 3/4 " wide roll up straps are located just above the window flap.  A 1" wide hook fastener strip is located around the outside seam of the window opening.  Two window walls are issued with each MCPS. (4) Entrance Way Wall.  The entrance way wall (4) is constructed similar to the plain wall except that there are no quick  release  female  fasteners  located  along  the  inside  top.    Additionally,  this  wall  incorporates  a  36"  wide  covered entrance way.  Inner blackout doors cover the entrance way opening in the wall.  A 1" wide pile fastener strip is sewn along its  top  edge.    A  1"  wide  hook  fastener  strip  is  located  along  the  top  of  the  entrance  way  wall  opening.    Left  and  right blackout  door  assemblies  are  sewn  to  the  outer  seams  of  the  entrance  way  wall  opening.    Both  have  two  poleholders located on the outside approximately 35" apart, and three buckle assemblies  with  quick  disconnect  female  fasteners  on the inside.  A grommet is located on each upper and lower corner of the left and right blackout door assemblies.  A male quick disconnect fastener is located on the front center of the entrance  way  roof.    An  identification  label  is  sewn  on  the inside of the wall.  The covered entrance way allows for entry into and exit from the tent, enhances ventilation and helps maintain light discipline.  One entrance way wall is issued with each MCPS. (5) Entrance Way/Window Wall Liner.  The entrance way/ window wall liner (5) is constructed similar to the plain wall liner except that it contains an approximately 6’1/2" high and 3’ wide door.  A quick release male fastener is located on the upper, inside edge of the door and a quick disconnect female fastener in corresponding location on the liner.  A strip of 1" pile fastener is located along the left side and along the top of the liner door opening.  A strip of 1" hook fastener is sewn to the outer edge and top of the door.  In addition seven quick release female fasteners are located on the outside along the door opening.  Three entrance way wall/window wall liners are issued with each MCPS. (6) Roof  Cap.    The  roof  cap  (6)  is  constructed  of  the  same  material  as  the  walls.    On  the  inside,  8"  wide reinforcements  are  located  along  the  front  and  rear,  with  quick  disconnect  female  fasteners  located  approximately  18" apart.  Two strips of 2" wide hook fastener are sewn to the reinforcement.  Along the sides,  16  1/2"  reinforcements  are located, with quick disconnect female fasteners spaced approximately 18" apart.  Two strips of 2" wide hook fastener are sewn to the reinforcement below the fasteners.  In addition, strap assemblies with quick disconnect fasteners are located on the upper part of the reinforcement.  An 11" x 24" 1-6







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.