• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REPAIR LIGHT SET - Contd - TM-10-5410-229-13P_120
REPAIR LIGHT SET - Contd - TM-10-5410-229-13P_122

TM-10-5410-229-13P Modular Command Post System (MCPS) Green NSN 5410-01-323-2454 Tan NSN 5410-01-334-7529 Manual
Page Navigation
  104    105    106    107    108  109  110    111    112    113    114  
TM 10-5410-229-13&P 5-11. REPAIR LIGHT SET - Cont’d 1. Remove Female Cable Assembly. (a) Remove end cap (1) on female power cord (2) from luminaire (3). (b) Remove lampholder (4) by depressing retainer connector (5). (c) Cut female power cord (2) wires from lampholder (4) and pull power cord (2) out of end cap (1). 2. Install Female Cable Assembly. (a) Insert loose wire end of new female power cord (2) through end cap (1) so that approximately three inches of the cord are inside the end cap (1). (b) Remove outer insulation from power cord (2) on inside of end cap (1), and approximately 1/2" from individual wires. (c) Solder power cord (2) wires to lampholder (4) wires. (d) Install lampholder (4). (e) Install end cap (1) onto luminaire (3). d. Remove and Install Male Cable Assembly. 5-13