REPAIR FIELD TABLE.
REPAIR FIELD TABLE - Contd - TM-10-5410-229-13P_116

TM-10-5410-229-13P Modular Command Post System (MCPS) Green NSN 5410-01-323-2454 Tan NSN 5410-01-334-7529 Manual
Page Navigation
  98    99    100    101    102  103  104    105    106    107    108  
TM 10-5410-229-13&P 5-10. REPAIR FIELD TABLE - Cont’d (2)   Install Leg Weldment. (a) Align new leg weldment (2) with bolt sleeve in top weldment (7) (b) Install screws (3), washers (4), nuts (5), and nylon washers (6), securing weldment (2) to table. (c) Install rivets (1), (See paragraph 5-6.b.  for rivet replacement procedures) holding braces to weldment (2). b. Remove and Install Brace. (1) Remove Brace. (a) Remove rivets (1) holding brace (2) to top weldment (3), and leg weldment (4).  (See paragraph 5-6.a. for rivet removal procedures). (b) Remove brace (2). 5-7