TM 10-5410-221-24
(15) Remove bolt (44), washer (45) and
angle (18) from receptacle box (19). Remove rivnut (15)
remove disconnect mounting bracket (46).
by drilling out using a drill bit with the same diameter as
(16) Remove bolt (47), washer (48) and
the rivnut. Remove box (19) per step (2) above.
remove pump mounting bracket (49).
(5) Remove screw (20) and remove cover
(17) Remove water box (51) from shelter by
(21), remove box (22) from panel per step (2) above.
removing rivets (50) from angles on interior and exterior
(6) Remove seal (23) from opening at bottom
of box.
Remove seal (24) by peeling from
c. Assembly Assemble the water box assembly
cemented area per paragraph 2'-20d.
(7) Remove ring assembly (28, 29) from
panel by removing bolt (25), washers (26, 27). Separate
guide.
d. Repair. Repair damage to honeycomb panel
fitting (33) from ring assembly (28, 29) by removing
screws (30) and washers (31, 32).
(8) Remove plate (35) by removing rivets
straighten any bent or dented brackets, or hinges using a
(34).
hammer, pliers, vise, or other suitable tool.
(9) Remove steps (38) by removing bolt (36)
and washer (37).
10-13.
Water Box Fixed End Panel Assembly
(10) Remove striker plate (41) by removing
screw (39). Remove insert (40) by drilling out using a
a. General. The water box fixed end panel is a
drill bit with the same diameter as the insert.
metal faced honeycomb core panel housing the water
(11) Remove bracket (45) and spacer (44) by
box assembly at the bottom edge of the panel (fig. 10-
removing bolt (42) and washer (43).
(12) Remove latch assembly (47) by removing
b. Removal.
screw (46).
(1) Remove gusset assembly from end panel
(13) Remove screw (48), washer (49) and
remove clamp assembly (50). Remove cable assembly
(2) Remove hinge half from water box fixed
(51) and remove lockwire and unscrew hook (52) from
turnbuckle (53). Unscrew turnbuckle (53) from terminal
(3) Remove electrical wiring assembly per
(54).
(14) Remove screw (55) and remove capstan
(56) from panel.
angles (2, 3) from bottom edge of panel, and remove
(15) Remove screw (57), rasher (.58) and
water box fixed end panel from -shelter.
remove spacer (59). Remove insert (60) by drilling out
c.. Disassembly. Disassemble water box fixed
using a drill bit with same size diameter as insert.
end panel assembly as required to replace damaged
(16) Remove tie down assembly (62) by
parts according to sequence of index numbers assigned
removing rivet (61).
(17) Remove spacer (64) by removing screw
(1) Remove screw (4) and cover (5) from
(63).
receptacle box (8). Remove rivet (6) and remove
(18) Remove bolt ('65), washers (66, 67) and
grounding angle (7) and remove receptacle box (8) from
remove guide assembly (68) from fixed end panel (69).
panel.
d. Repair. Repair damage to honeycomb panel
(2) Remove screw (4), cover (9) and remove
receptacle box (10) from panel by running a knife or
straighten any bent plates, latches, angles, or extrusions
other suitable tool around edge to separate from core.
using hammer, pliers, vise or other suitable tool.
(3) Remove screw (11), washer (12) and
remove ground rod (13) from panel.
(4) Remove cover (16) by removing screw
(14). Remove rivet (17) and grounding
.
10-23