TM 10-5410-221-24
the receptacle in the event the load reaches 1(amps, and
the CB9 circuit breaker opens in the event the load
and III for wiring schematic and wiring terminal
reaches 5 amps. Opening of the circuit breaker is
identification.
indicated by the extension of the reset button. The circuit
breaker is reset by pressing in on the reset button
6-39.
CB1, C86, CB7, and CB1 5 Circuit Breakers
b.
Removal.
a. General. CB1, CB6, CB7, and CB15 circuit
(1) Remove the screws from the terminals
breakers (122, fig. 6-22) provide protection against
and disconnect electrical leads (X422J12, X452H12,
damage resulting from an overload in the 400 Hertz left
X466A16, X452K12, X467A12 from circuit breakers CB8
hand and right hand receptacles, and the 28 vdc surgical
and emergency light circuits. The CB1, CB6, CB7, and
(2) Remove nuts (114) and washer (115)
CB15 circuit breakers open the circuits or receptacles in
used to secure circuit breakers (116 to panel (123), and
the event the load reaches 20 amperes. Opening of the
remove circuit breaker by pulling from rear of panel.
circuit breaker is indicated by the extension of the reset
button. The circuit breaker is reset by pressing in on the
c. Installation. Install circuit breakers in reverse
reset button.
order of removal using figure 6-22 as a guide referring to
b.
Removal.
wiring schematic and wiring terminal identification
(1) Remove the screws (17) from the
terminals and disconnect electrical leads (P653C16,
6-38.
CB17, CB18, and CB19 Circuit Breakers
P667A16) from CB1 circuit breaker. Remove electrical
a. General.
CB17, CB18, and CB19 circuit
leads (X451G12, X451H12, X465B12, X465A12) from
breakers (119, fig. 6-22) provide protection against
CB6 circuit breaker. Remove electrical leads (X450G12,
damage resulting from an overload in the water hose or
X450H12,
X464B12,
X464A12) from CB7 circuit
water line receptacles. The CB17, CB18, and CB19
breaker. Remove electrical leads (X498A12, X482A12)
from CB15. circuit breaker.
load reached 15 amps. Opening of the circuit breaker is
(2) Remove nuts (12) and washers (121)
indicated by the extension of the reset button. The circuit
used to secure circuit breakers (122) to panel (123) and
breaker is reset by pressing in on the reset button.
remove by pulling from rear of panel (123).
b.
Removal.
c. Installation. Install circuit breaker in reverse
(1) Remove screws (17) from the terminals
order of removal using figure 6-22 as a guide referring to
and disconnect electrical lead (X452F10, X452G12,
H473A12) from CB1 circuit breaker. Remove electrical
III for wiring schematic and wiring terminal identification.
lead (X452G12, X451F10, X469A12, X469B12 from
CB18 circuit breaker.
Remove electrical leads
6-40.
TB1 Terminal Board
(X450G12, X450F10, H472A12) from CB19 circuit
breaker.
a. Removal. Remove terminal board TB1 (52, fig.
6-22) according to
sequence of
index numbers assigned
(118) used to secure circuit breakers (119) to panel, and
remove by pulling from rear of panel (123).
(1) Remove cover (49) from TB1 terminal
board (52).
c. Installation. Install circuit breakers in reverse
order of removal using figure 6-22 as a guide, referring to
6-60