TM 10-5410-221-24
terminal identification and figure 1-7 for wiring schematic.
(3) Remove cover from raceway adjacent to
power out panel and remove all clamps securing the
harness to the electrical raceway. Remove the harness
6-5.
400 Hertz Power (power out)
Wiring
and connector gasket.
Harness and Connector Assembly
c. Disassembly. Disassemble 400 Hertz harness
and connector assembly as required to replace damaged
a. General. The 400 Hertz (power out) wiring
terminals according to sequence of index numbers
harness and connector assembly provides for connection
assigned to figure 6-3 and by removing terminals (1, 2)
of additional shelters or for other external 120/208 volts,
from electrical leads.
400 Hertz power requirements to the power out box
d. Repair.
If possible, straighten any bent
assembly. The wiring harness assembly consists of a
connector pins. Inspect wires for abrasions and cuts of
connector and five electrical leads with terminals.
insulation. Minor outs and abrasions are acceptable and
b. Removal.
may be repaired by wrapping with vinyl tape. Replace
(1) Remove the nuts, washers, and screw
harness assembly if individual wires are cut or otherwise
securing the 400 Hertz harness and connector assembly
damaged.
(8, fig. 6-1) to the power out panel assembly.
Note. Cuts or abrasions of harness assemblies
(2) Remove the electrical lead from terminals
may be due to sharp edges of electrical raceways,
1 through 5 on TB1 terminal board in the power
handling. The cause shall be determined and eliminated
before installation of the harness assemblies.
Figure 6-3. 400 Hertz power out harness assembly.
6-3