TM 10-5410-221-14/1
1. Screw (4)
14.
Seal
27. Pin (2)
40.
Receptacle
2. Washer (4)
15.
Rivet (3)
28. Fastener stud (2)
41.
Rivet (20)
3. Cover ay
16.
Door ay
29. Rivet (4)
42.
Nut plate (10)
4. Rivet (10)
17.
Seal
30. Receptacle
43.
Insulation
5. Hinge
18.
Seal
31. Seal
44.
Bolt (5)
6. Seal
19.
Seal
32 Insulation
45.
Washer (5)
7. Seal
20.
Seal
33. Bolt (8)
46.
Bracket, disconnect mtg
8. Seal
21.
Pin
34. Washer (8)
47.
Bolt (4)
9. Rivet (5)
22.
Fastener stud
35. Bracket, receptacle mtg
48.
Washer (4)
10.Door ay
23.
Rivet (8)
36. Bolt (8)
49.
Bracket, pump mtg
11. Seal
24.
Cover ay
37. Washer (8)
50.
Rivet (29)
12. Seal
25.
Seal
38. Bracket, receptacle mtg
51.
Water box ay
13. Seal
26.
Hinge
39. Rivet (2)
(1) Install water box (51, fig. 8-8) to shelter by
a. General.. The box fixed end panel is a metal
installing rivets (50) to angles on interior and exterior of
faced honeycomb core panel housing the water box
box.
(2) Install bolt (.17), washer (48) and install pump)
b. Removal.
mounting bracket (49).
(1) Remove gusset assembly from end panel and
(3) Install bolt (44), washer (45) and install
roof panel per paragraph 8-108).
disconnect mounting bracket (46).
(2) Remove hinge half from water box fixed panel
(4) Install insulation (43) to cemented area. (5)
Install rivet (41) and nut plate (42). Install rivet (39) to
(3) Remove electrical wiring assembly per chapter 6,
install receptacle (,10) to bracket (38).
section II.
(6) Install bolts (:3(;), washers (37) and install
(4) Remove rivets (1.FO-7) located at back of
receptacle mounting bracket (38).
manual) and move angles (2 and 3) from bottom edge
(7) Install bolts (3.3), washers (34) and install
of panel, and remove water box fixed end panel from
shelter.
(8) Install seals (:l) and insulation to cemented area.
c. Disassembly. Disassemble water box fixed end
(9) Install rivet (29) and install receptacle (30). Install
panel assembly as required to replace damaged parts
pin (27) and install fastener stud(28)to cover assembly
according to sequence of index numbers assigned to
(2-1).
FO-7 (located in back of manual) and observing the
(10) Install hinge (26i) by installing rivet (25). Install
following:
rivet (23) and install covet' assembly (24).
(1) Remove screw (4, FO-7) and cover (5) from
(11) Install pin (21) and install fastener stud (22) to
receptacle box (8). Remove rivet (6) and remove
cover assembly k3).
grounding angle (7) and remove receptacle box (8) from
(12) Install rivet (15), door assembly (16) and install
panel.
seals (17. 18, 19 and 20) to cemented area.
(2) Remove screw. (4), cover (9) and remove
(13) Install rivets (9). door assembly (10) and install
receptacle box (10) from panel by running a knife or
seals (11, 12, 13 and 14) to cemented area.
other suitable tool around edge to separate from core.
(14) Install hinge (5) to cover assembly (3) by
(3) Remove screw (11), washer (12) and remove
installing rivet (4). Install seals (6, 7, and 8) to cemented
ground rod (13) from panel.
area.
(4) Remove cover (16G) by removing screw (14).
(15) Install screw (1, fig. 8-8), washer (2) and install
Remove rivet (17) and grounding angle (18) from
cover assembly.
receptacle box (19). Remove rivnut (15) by drilling out
(16) Install electrical system components as outlined
using a drill bit with the same diameter as the rivnut.
in chapter 6, section II.
Remove box (19) per step (2) above.
(17) Install all plumbing system components per
(5) Remove screw (20) and remove cover (21),
paragraphs 4--40 and 10-5.
remove box (22) from panel per step (2) above.
d. Repair). Repair damage to honeycomb panel
(6) Remove seal (23) from opening at bottom of
extrusion. Remove seal (24) by peeling from cemented
straighten any bent or dented brackets, or hinges using a
area.
hammer, pliers, vise, or other suitable tool.
8-13. Water Box Fixed End Panel Assembly
8-21