TM 10-5410-221-14/1
Figure 6-3. Power Output Panel A8ssembly (TS 013782)
Section II. HARNESS ASSEMBLIES, WATER TUNNEL AND WIRE REPAIR INSTRUCTIONS
connecting wire must be of sufficient
6-3. General
strength to allow pulling the replacement
This section contains the electrical harness
harness into raceway during installation
assemblies and wires used to interconnect the electrical
procedure. (Refer to FO-3 located in
components of the electrical system. They consist of a
back of manual.)
400 Hertz and 60 Hertz power harness assemblies.
Surgical and air lock lights harness assembly, lights
6-4. 400 Hertz (Power In) Harness and Connector
harness assemblies, surgical lights harness assemblies,
under floor heater harness assemblies and shelter loose
Assembly (Water Tunnel)
wire assemblies.
a. Removal. Jack up the shelter to gain enough
NOTE
height for access to the electrical cable raceway under
When removing the harness assemblies
the shelter and remove the access panels by removing
and loose wire assemblies from the
bolts (1, fig. 6-4), washers (2 and 3) and panels (4, 5, 6,
shelter electrical raceways, an electrical
and 7).
wire or other flexible cable (fishing tool)
must be tied to the harness or wire
assembly end and pulled into the
raceway as the harness or wire
assembly, is being pulled out. The
6-4